Refrigerant
R134a
1,1,1,2-Tetrafluoroethane
Single-component HFC refrigerant for air-conditioning and refrigeration equipment designed for R134a. Supplied in a cylinder with a printed carton.

- Refrigerant
- R-134a
- Formula
- CH₂FCF₃
- CAS number
- 811-97-2
- ASHRAE safety group
- A1
- Ozone depletion potential
- 0
Overview
R134a (1,1,1,2-tetrafluoroethane) is a single-component hydrofluorocarbon refrigerant. It has no ozone depletion potential and an ASHRAE A1 safety classification. It is used in chillers, medium-temperature commercial refrigeration and in servicing mobile air-conditioning and other equipment designed for it.
DICCO COOL R134a is supplied in a light blue cylinder with a printed carton marked for HVAC use. We work with importers, distributors and contractors on wholesale volumes. Technical documentation is shared as part of the commercial conversation.

Concept visual of the DICCO COOL R134a pack. Illustrative only.

Applications
R134a is suitable only for equipment designed or approved for it. It is not a drop-in replacement for other refrigerants. As a hydrofluorocarbon it is subject to phase-down and use restrictions in many countries under the Kigali Amendment to the Montreal Protocol and national rules. Check local regulations and the equipment manufacturer's requirements before purchase or use.
Chillers
Centrifugal and screw chillers for commercial buildings and process cooling are a long-established home for R134a. Initial charge and service top-ups follow the equipment manufacturer's specification.
Commercial refrigeration
Medium-temperature display cabinets, reach-in coolers and cold rooms built for R134a, used in retail, food service and storage at chilled rather than frozen temperatures.
Mobile air-conditioning service
Servicing of vehicle air-conditioning systems originally designed for R134a, carried out by workshops with recovery and recharge equipment.
Domestic and light commercial appliances
Service and repair of refrigerators, freezers, water coolers and similar appliances manufactured for R134a.
Transport and specialist equipment
Transport refrigeration units, heat pumps, dehumidifiers and specialist cooling equipment where the manufacturer specifies R134a.
Specifications
Identification values are printed on the pack. Physical and environmental values are published reference data for the R-134a substance, not a batch specification.
- Printed on pack
- R-134a reference data
Batch values such as purity, moisture and acidity are given on the technical data sheet. Request a copy
| Refrigerant designation | R-134a | Printed on pack |
|---|---|---|
| Chemical name | 1,1,1,2-Tetrafluoroethane | Printed on pack |
| CAS number | 811-97-2 | Printed on pack |
| Chemical formula | CH₂FCF₃ | R-134a reference data |
| Refrigerant type | Single-component HFC | R-134a reference data |
| Molecular weight | 102.03 g/mol | R-134a reference data |
|---|---|---|
| Boiling point at 101.3 kPa | −26.1 °C / −14.9 °F | R-134a reference data |
| Critical temperature | 101.1 °C / 213.9 °F | R-134a reference data |
| Critical pressure | 4.06 MPa / 588.7 psia | R-134a reference data |
| ASHRAE 34 safety group | A1 (lower toxicity, no flame propagation) | R-134a reference data |
|---|---|---|
| Flammability | Non-flammable liquefied gas | Printed on pack |
| Ozone depletion potential | 0 | R-134a reference data |
| Global warming potential | 1,430 (IPCC AR4, 100-year) | R-134a reference data |
| UN number | UN 3159, Class 2.2 | R-134a reference data |
Packaging
Details as printed on the supplied pack. Cylinder type, valve connection, pallet and container quantities are confirmed with each quotation.
- Format
- Refrigerant cylinder supplied in a printed carton
- Net weight (as printed)
- 30 lb / 13.6 kg
- Cylinder colour
- Light blue
- Labelled use
- For HVAC; for air-conditioning systems
Safety and handling
R134a is a liquefied gas under pressure. Handling, charging and recovery should be carried out only by trained, appropriately certified technicians, following the product Safety Data Sheet and local regulations. The SDS takes precedence over the guidance below.
- Pressure
- Contains gas under pressure and may burst if heated. Keep cylinders away from heat sources and direct sunlight, and never use a flame to warm a cylinder.
- Cold contact
- Liquid refrigerant and rapidly expanding vapour can cause frostbite. Wear insulated gloves and eye protection when connecting or disconnecting.
- Ventilation
- The vapour is heavier than air and can displace oxygen in low or enclosed spaces. Work in well-ventilated areas and treat pits and plant rooms with care.
- Storage and transport
- Store upright in a cool, dry, ventilated area. Secure cylinders against falling and protect valves during transport.
- Decomposition
- At high temperatures, for example in contact with flames or hot surfaces, R134a can decompose into toxic and corrosive products. Do not smoke or use naked flames near leaks.
- Environment
- Do not vent to atmosphere. Recover refrigerant with suitable equipment and return it for reclamation or destruction in line with local rules.
Technical documents
Product documents are shared directly with trade buyers so that each market receives the right version and language.
- Request document: R134a Safety Data Sheet
R134a Safety Data Sheet
Hazard identification, first aid, firefighting, handling, storage, exposure controls and transport information.
- Request document: R134a Technical Data Sheet
R134a Technical Data Sheet
Physical properties and batch specification values, including purity, moisture and acidity limits.
Request R134a pricing for your market